Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
China Pharmacy ; (12): 2539-2542, 2017.
Article in Chinese | WPRIM | ID: wpr-619798

ABSTRACT

OBJECTIVE:To establish the method for the rapid determination of stilbene glycoside in Shouwu pills. METH-ODS:HPLC method was used to determine the content of stilbene glycoside in Shouwu pills(as measured value). The determina-tion was performed on ODS-C18 column with mobile phase consisted of acetonitrile-water(25:75,V/V)at the flow rate of 0.8 mL/min. The detection wavelength was set at 320 nm,and the column temperature was 30 ℃. The sample size was 10 μL. The partial least square method-near infrared diffuse reflectance spectrophotometry was used to establish quantitative calibration model for pre-dicting the content of stilbene glycoside in Shouwu pills. According to measured value,76 calibration set samples and 24 validation set samples were collected. Standard normalization method and first-order derivative method combined with Savitzky-Goly filter method were used for spectrum pretreatment. The optimal band ranged 9000-4150 cm-1,and main component factor was 12. RE-SULTS:The content determination method of stilbene glycoside in Shouwu pills was in line with the requirements. The correlation coefficients,the root-mean-square error of calibration,the root-mean-square error of predication and the root-mean-square error of cross-validation(RMSECV)of the quantitative calibration model were 0.99190,0.0201,0.0236 and 0.07629. There was no sta-tistical significance between predicted value and measured value(P>0.05). CONCLUSIONS:The method is accurate,stable and simple,and can be used for rapid determination of stilbene glycoside in Shouwu pills.

2.
Herald of Medicine ; (12): 1633-1636, 2015.
Article in Chinese | WPRIM | ID: wpr-484609

ABSTRACT

Objective To determine the moisture content in Polygoni multiflori Radix rapidly by near-infrared spectroscopy. Methods The moisture content of the samples were determined by oven drying method and the near-infrared spectrum data were collected by near-infrared spectroscopy.The quantitative test model of moisture content in Polygoni multiflori Radix was established by chemometrics methods and was validated with validation samples. Results The correlation coefficients, root-mean-square error of calibration (RMSEC), root-mean-square error of predication (RMSCP) and the root-mean-square error of cross-validation ( RMSECV ) of the calibration model was 0. 984 75, 0. 161, 0. 181 and 0. 471 64, respectively.The absolute deviation of the analytical and predictive values of 21 validation samples was -0.35%-0.28%, and the average recovery was 99. 87%. Conclusion Near-infrared spectroscopy can be used to determine the moisture content of Polygoni multiflori Radix rapidly and accurately.

SELECTION OF CITATIONS
SEARCH DETAIL